FIGURE 4 - TIE STRAP INSTALLATION
MODIFICATION: MOISTURE SHIELD The moisture shield must be modified to allow the installation of a tie strap to hold the shield to the solenoid
valve. A "V" shaped slot must be cut in both sides of the shield opposite the holed tab side of the shield (see Figure No. 3). After the
modification to the shield and solenoid bracket have been completed, install the shield on the solenoid. Install the tie strap, P/N
15501907, tightly around the solenoid and shield (see Figure No. 4) and cut off the excess length. Make sure that the tie strap is
positioned between the center hose port and the electrical connection to the solenoid valve.