Compressor Shaft Seal

Seal Leak Detection

A shaft seal should not be changed because of small amounts of oil found on an adjacent surface but only after actual refrigerant leakage is found using
an approved leak detector, J 39400 or equivalent.

Remove or Disconnect

1. Recover the refrigerant using J 39500-GM.
2. Loosen and reposition compressor in mounting brackets, if necessary.
3. Remove clutch plate and hub assembly from compressor as described in minor repairs.
4. Remove the shaft seal retainer ring, using snap ring pliers J 5403.
5. Thoroughly clean inside of compressor neck area surrounding the shaft, the exposed portion of the seal, the retainer ring groove and the shaft

itself. Any dirt or foreign material getting into compressor may cause damage.

6. Fully engage the knurled tangs of Seal Remover-Installer J 23128-A into the recessed portion of the Seal by turning the handle clockwise. Remove

the Seal from the compressor with a rotary-pulling motion. Discard the seal. The handle must be hand-tightened securely. Do not use a wrench or
pliers.

7. Remove and discard the seal seat O-ring from the compressor neck using O-ring remover J 9553-01.
8. Recheck the shaft and inside of the compressor neck for dirt or foreign material and be sure these areas are perfectly clean before installing new

parts.

Clean

^

Thoroughly clean O-ring seal groove in front head.

NOTICE: Seals should not be re-used. Always use a new specification service seal on rebuild. Be sure that the seal to he installed is not scratched
or damaged in anyway. Make sure that the seal seat and seal are free of lint and dirt that could damage the seal surface or prevent sealing.

Install or Connect

1. Dip the new seal seat O-ring in clean 525 viscosity refrigerant oil and assemble onto O-ring installer J 33011.
2. Insert the O-ring installer J 33011 into the compressor neck until the installer "bottoms." Lower the moveable slide of the O-ring installer to

release the O-ring into the seal O-ring lower groove. (The compressor neck top groove is for the shaft seal retainer ring.) Rotate the installer to seat
the O-ring and remove the installer.

3. Dip the new seal in clean 525 viscosity refrigerant oil and assemble seal to Seal Installer J 23128-A, by turning handle clockwise. The stamped

steel case side of the lip seal must he engaged with knurled tangs of installer so that flared-out side of lip seal is facing and installed towards the
compressor. Install seal protector J 34614, in the seal lip and place over the compressor shaft, and push the seal in place with a rotary motion or
place the seal protector J 34014 over end of compressor shaft, and slide the new seal onto the shaft with a rotary motion until it stops. Take care
not to dislodge the O-ring. Be sure the seal makes good contact with the O-ring. Disengage the installer from the seal and remove the installer J
23128-A and the seal protector J 34614.

NOTICE: Handling and care of seal protector is important. If seal protector is nicked or the bottom flared, the new seal may be damaged during
installation.

4. Install the new seal retainer ring with its flat side against the Seal, using Snap-Ring Pliers J 5403. See illustration. Use the sleeve from O-ring

installer J 33011 to press in on the seal retainer ring so that it snaps into its groove.

5. To leak test, install compressor leak test fixture J 39893 on rear head of compressor and connect gage charging lines and J 39500-GM Refrigerant

Recovery System. Pressurize suction and high-side of compressor with R-134a Refrigerant. Temporarily install (M9 x 1.25 thread on shaft) nut
and, with the compressor in horizontal position, rotate the compressor shaft in normal direction of rotation several turns by hand. Leak test the seal
area and correct and leak found. Recover the refrigerant. Remove shaft nut.

6. Remove any excess oil resulting from installing the new seal parts from the shaft and inside the compressor neck.
7. Install the clutch plate and hub assembly as described in minor repair procedures.
8. Reinstall compressor belt and tighten bracket.
9. Evacuate and charge the refrigerant system.