G 3500 1 Ton Van V8-350 5.7L VIN E 2-bbl (1984)
Canister Purge Solenoid: Description and Operation
Computer Command Control (C3) System
ECM controls vacuum to the purge valve through the purge solenoid.
-
When the engine is cold (open loop), the solenoid valve is energized, blocking vacuum to the purge valve.
-
When the engine is warm (closed loop) and operating above a preset engine or vehicle speed the solenoid valve is de-energized, allowing
vacuum to be applied to the purge valve.