gmc Workshop Repair Guides

GMC Workshop Service and Repair Manuals

Air Conditioning Switch > < Mechanical Specifications|Page 11655
Page 2
background image

6. Refrigerant hose to accumulator.

Tighten

-

Hose to 41 Nm (30 lb ft).

7. Pressure cycling switch.
8. Electrical connectors, as necessary.
9. Negative battery cable.

10. Charge system.

-

Check system for leaks.