Control Assembly: Customer Interest
A/C - Loss of Mode/Temperature Control

File In Section: 01 - HVAC 

Bulletin No.: 01-01-39-007

Date: January, 2002

TECHNICAL

Subject: 
Loss Of HVAC System Mode and/or Temperature Control 
(Reroute Wiring Harness)

Models: 
1999-2002 Chevrolet and GMC C/K Pickup Models (Silverado and Sierra) 1999-2002 Chevrolet and GMC C/K Utility Models (Avalanche, Suburban,
Tahoe, Yukon, Yukon XL, Denali) 2001 GMC Sierra C3
2002 GMC Sierra Denali
2002 Cadillac Escalade, Escalade EXT

Condition

Some customers may comment that they cannot control the HVAC system modes and/or the temperature. These concerns may be intermittent.

Cause

There may be poor terminal contact and/or bent terminals in connectors C206 (RPO C68 automatic HVAC controls) or C296 (RPO C60 manual HVAC
controls). Excessive tension on the wires due to the wiring harness being misrouted in the instrument panel carrier may cause these conditions.

Correction

1.

Remove the Air Bag fuse.

2.

Disconnect the steering wheel and instrument panel (IP) air bag connectors. Refer to the SIR subsection of the Restraints section of the Service
Manual for connector locations.

3.

Remove the IP upper trim pad.

4.

Locate connector C206 (6 cavities) or C296 (8 cavities). The connector is attached to a metal brace on the far right side of the IP carrier above the
IP air distributor duct.

5.

Inspect the routing of the wiring harness to the connector. The proper routing of the wiring harness is above the air distributor duct with no tension
on the terminals in the connector. The routing is improper if the wiring harness is below the air distributor duct with excessive tension on the
terminals in the connector. The excessive tension may cause poor terminal contact, resulting in open circuits, in the connector. The wires may also
pull the terminals out of the connector or pull out of the terminal itself.

6.

If the harness is routed properly, contact Technical Assistance for further information.

7.

If the harness is misrouted, remove the connector from the brace.

8.

Disconnect the connector.

9.

Perform a pin drag test on the female terminals.

10.

Inspect the male terminals for straightness.

11.

Inspect the wire to terminal connection to insure that no wires have pulled out of the terminals.

12.

Reroute the wiring harness above the air distributor duct.

13.

Firmly reconnect and reseat the connector.

14.

Reattach the connector to the metal brace.

15.

Reinstall the IP upper trim pad.