K 2500 Suburban 4WD V8-454 7.4L VIN N TBI (1995)
Auxiliary Blower Motor/Resistor
Remove or Disconnect
1. Negative battery cable.
2. Right rear quarter trim panel cover.
3. Electrical connectors, as necessary.
4. Screws (30).
5. Blower motor resistor (31).
Install or Connect
1. Blower motor resistor (31).
2. Screws (30). Tighten Screws (30) to 1.9 Nm (17 lb in).
3. Electrical connectors, as necessary.
4. Right rear quarter trim panel cover.
5. Negative battery cable.
-
Check circuit operation.