gmc Workshop Repair Guides

GMC Workshop Service and Repair Manuals

Hose/Line HVAC|Specifications|Page 10152 > < Compressor Pressure Relief Valve Removal (HT6/HD6)|Page 10148
Page 1
background image

Hose/Line HVAC: Specifications

Accumulator to Front Evaporator Connection.............................................................................................................................................. 41 N.m (30 lb ft)
Auxiliary Refrigerant Hose Mounting Clip Screws........................................................................................................................................ 6 N.m (53 lb in)
Auxiliary Evaporator Hose to Auxiliary Evaporator..................................................................................................................................... 17 N.m (13 lb ft)
Auxiliary Evaporator to Auxiliary Compressor Hose................................................................................................................................... 32 N.m (24 lb ft)
Compressor/Condenser Hose to Accumulator............................................................................................................................................... 41 N.m (30 lb ft)
Compressor/Condenser Hose to Auxiliary Compressor Hose....................................................................................................................... 24 N.m (18 lb ft)
Compressor/Condenser Hose to Compressor Bolt........................................................................................................................................ 34 N.m (25 lb ft)
Compressor/Condenser Hose to Condenser.................................................................................................................................................. 24 N.m (18 lb ft)
Evaporator Tube to Auxiliary Evaporator Hose............................................................................................................................................ 24 N.m (18 lb ft)
Evaporator Tube to Condenser...................................................................................................................................................................... 24 N.m (18 lb ft)
Evaporator Tube to Front Evaporator........................................................................................................................................................... 24 N.m (18 lb ft)

Hose/Line HVAC|Specifications|Page 10152 > < Compressor Pressure Relief Valve Removal (HT6/HD6)|Page 10148