gmc Workshop Repair Guides

GMC Workshop Service and Repair Manuals

Engine - Coolant Substitutes|Page 1995 > < Engine - Coolant Substitutes
Page 1
background image

Coolant: Technical Service Bulletins
Engine Coolant - Testing Information

GMC NUMBER:

90-T-01

GROUP: 6B - Engine Cooling

DATE: May, 1989

CORPORATE
NUMBER:966202R

SUBJECT: ENGINE COOLANT TESTING

MODELS: ALL 1988-1990 MODEL YEAR TRUCKS

This information supersedes information provided in the December Transportation Technicians Guild. Due to a worldwide shortage of "Ethylene
Glycol" in 1988, some coolant manufacturers have started to mix other types of glycol in their coolant formulations; propylene glycol is the most
common new ingredient. A hydrometer will not always provide a correct measurement of freeze protection when anything other than ethylene glycol and
water is being tested. The degree of inaccuracy will vary depending on the proportion of other glycols present in the coolant. All 1989 model GMC
trucks are produced with coolant that can be accurately measured with a hydrometer; however, when the type and quantity of coolant being measured is
unknown, such as a customer vehicle that has accumulated mileage, use of a refractometer is recommended. Hydrometers test the amount of glycol in a
mixture by measuring the specific gravity of the mixture; the more ethylene glycol, the higher the float balls go, and the better the freeze protection.
Because ethylene glycol and propylene glycol do not have the same specific gravities, hydrometer readings of mixtures containing propylene glycol give
incorrect values.

As the shortage of "ethylene glycol" continues and/or worsens, more and more variations in antifreeze formulas will be marketed. It is, therefore,
recommended that you purchase a "refractometer" and encourage your technicians to use it. Refractometers test for the amount of glycol in a coolant
mixture by measuring the speed of light as it passes through the fluid and are not affected by the specific gravity of the glycol. The freeze protection of
solutions of ethylene glycol in water, solutions of propylene glycol in water, and solutions of mixtures of propylene glycol and ethylene glycol in water
may all be tested with sufficient accuracy using a refractometer. Refractometers are available from several sources including:

Kent Moore*

J23688 Fahrenheit Scale
J26568 Celsius Scale

Toll-Free Number 1-800-345-2233

Misco Products*

Toll-Free Number 1-800-358-1100

IMPORTANT:Refractometers and hydrometers test only the FREEZE PROTECTION provided by a coolant.

*

"We believe these sources to be reliable. There may be additional manufacturers of such equipment. General Motors does not endorse, indicate
any preference for, or assume any responsibihty for the products or equipment from these firms or any such items which may be available from
other sources."

Engine - Coolant Substitutes|Page 1995 > < Engine - Coolant Substitutes