gmc Workshop Repair Guides

GMC Workshop Service and Repair Manuals

Diagram Information and Instructions|Page 9590 > < Diagram Information and Instructions|Page 9588
Page 18
background image

A grounded circuit is like a short circuit but the current flows directly into a ground circuit that is not part of the original circuit. This may be
caused by a wire rubbing against the frame or body. Sometimes a wire will break and fall against metal that is connected electrically to the ground
side of the voltage supply. A grounded circuit may also be caused by deposits of oil, dirt, or moisture around connections or terminals, which
provide a good path to ground.

Handling and Measuring Procedures

Fig. 1  ESD Symbol

Fig. 2  Typical Schematic W/ESD Symbol

ELECTROSTATIC DISCHARGE (ESD) SENSITIVE DEVICES

All ESD sensitive components are Solid State and the following information applies to them.  The ESD symbol, Fig. 1, is used on schematics to
indicate which components are ESD sensitive, Fig. 2. When handling any electronic part, the service technician should follow the guidelines
below to reduce any possible electrostatic charge build-up on the service technician's body and the electronic part in the dealership. If it is not
known whether or not a component is ESD sensitive, assume that it is.

HANDLING PROCEDURES

1. Always touch a known good ground before handling the part. This should be repeated while handling the part and more frequently after sliding

across the seat, sitting down from a standing position or walking the distance.

2. Avoid touching electrical terminals of the part, unless so instructed by a written diagnostic procedure.
3. When using a voltmeter be sure to connect the ground lead first.
4. Do not open package until it is time to install the part.
5. Before removing the part from its package, ground the package to a known good ground on the vehicle.

MEASURING PROCEDURES

The circuits shown within the boxes are greatly simplified. Do not troubleshoot by measuring resistance at any terminal of these devices unless so
instructed by a written diagnostic procedure. Due to the simplification of the schematics, resistance measurements could be misleading, or could
lead to electrostatic discharge.

Typical Electrical Repair

TYPICAL ELECTRICAL REPAIR

An open circuit is an incomplete circuit. Power cannot reach the load or reach ground. If a circuit is open, active components do not energize. A
short circuit is an unwanted connection between one part of the circuit and either ground or another part of the circuit. A short circuit causes a fuse
to blow or a circuit breaker to open.

SHORT CIRCUITS CAUSED BY DAMAGED WIRE INSULATION

^

Locate the damaged wire.

^

Find and correct the cause of the wire insulation damage.

^

For minor damage, tape over the wire. If damage is more extensive, replace the faulty segment of the wire.

Circuit Protection Devices

DESCRIPTION:

The purpose of circuit protection is to protect the wiring assembly during normal and overload conditions. An overload is defined as a current
requirement that is higher than normal. This overload could be caused by a short circuit or system malfunction. The short circuit could be the