gmc Workshop Repair Guides

GMC Workshop Service and Repair Manuals

Surge Tank Hose Replacement - Inlet|Page 4545 > < Surge Tank Hose Replacement - Inlet|Page 4543
Page 3
background image

Notice:  Refer to Fastener Notice in Service Precautions.

1. If replacing the water crossover install the following:

1.1.

Thermostat (3)

1.2.

Water outlet (1)

1.3.

Water outlet bolts (2)

^

Tighten the water outlet bolts to 30 Nm (22 ft. lbs.).

2. Install NEW water crossover gaskets.
3. Install the water crossover.
4. Install the water crossover bolts.

^

Tighten the water crossover bolts to 50 Nm (37 ft. lbs.).

5. Install the generator bracket.
6. Install the generator bracket stud.

Surge Tank Hose Replacement - Inlet|Page 4545 > < Surge Tank Hose Replacement - Inlet|Page 4543