gmc Workshop Repair Guides

GMC Workshop Service and Repair Manuals

Technician Safety Information|Page 10427 > < Technician Safety Information|Page 10425
Page 1
background image

Alternator: Description and Operation

AD-230 and AD-244 Series generators feature a high ampere output per pound of weight. The A stands for air cooling. The D stands for dual internal
fans. The 2 stands for Gen II while the 30 and 44 are the measurements, in millimeters, of the outside diameter of the stator laminations. Neither
generators are serviceable and must be replaced

The charge indicator turns on when the ignition switch is closed and the engine is not running, and turns off when the engine is running. If the charge
indicator is on with the engine running, this indicates a charging system condition. The indicator will glow at full brilliance, not half lit, if any of the
following conditions occur:

-

Any charging condition

-

System voltage is too high or too low.

The regulator limits system voltage by controlling the rotor field current. When the field current is on, the regulator switches the rotor field on and off at
a fixed rate of about 400 cycles per second. By varying the overall on/off time, correct average field current for proper system voltage control is

Technician Safety Information|Page 10427 > < Technician Safety Information|Page 10425