Turn ON the circuit and/or system with a scan tool in Output Controls.

-

Turn ON the switch for the circuit and/or system being tested.

3. Select the V (AC) or V (DC) position on the DMM.
4. Connect the positive lead of the DMM to the point of the circuit to be tested.
5. Connect the negative lead of the DMM to a good ground.
6. The DMM displays the voltage measured at that point.

Measuring Voltage Drop

NOTE:  Refer to Test Probe Notice in Cautions and Notices.

The following procedure determines the difference in voltage potential between two points.

1. Set the rotary dial of the DMM to the V (DC) position.
2. Connect the positive lead of the DMM to one point of the circuit to be tested.
3. Connect the negative lead of the DMM to the other point of the circuit.
4. Operate the circuit.
5. The DMM displays the difference in voltage between the two points.

Probing Electrical Connectors

IMPORTANT:  Always be sure to reinstall the Connector Position Assurance (CPA) and Terminal Position Assurance (TPA) when reconnecting
connectors or replacing terminals.

Frontprobe

Disconnect the connector and probe the terminals from the mating side (front) of the connector.

NOTE:  Do not insert test equipment probes into any connector or fuse block terminal. The diameter of the test probes will deform most terminals. A
deformed terminal can cause a poor connection, which can result in system failures. Always use the J 35616-A Connector Test Adapter Kit or the J
42675 Flat Wire Probe Adapter Kit in order to frontprobe terminals. Do not use paper clips or other substitutes as they can damage terminals and
cause incorrect measurements.

Backprobe

Do not disconnect the connector and probe the terminals from the harness side (back) of the connector.

IMPORTANT:
-

Backprobe connector terminals only when specifically required in diagnostic procedures.

-

Do not backprobe a sealed (Weather Pack®) connector, less than a 280 series Metri-Pack connector, a Micro-Pack connector, or a flat wire (dock
and lock) connector.

-

Backprobing can be a source of damage to connector terminals. Use care in order to avoid deforming the terminal, either by forcing the test probe
too far into the cavity or by using too large of a test probe.

-

After backprobing any connector, inspect for terminal damage. If terminal damage is suspected, test for proper terminal contact.

Salt Water Spray

Some compounds possess the ability to conduct electricity when dissolved in water such as ordinary salt. By mixing table salt with water in sufficient
quantities, you can enhance the conductive properties of water so that any circuit which may be sensitive to moisture will more readily fail when liberally
sprayed with this mixture.