18. Install the generator positive cable and the retaining nut to the generator.

^

Tighten the generator positive cable nut to 9 Nm (80 inch lbs.).

19. Connect the generator electrical connector.

20. Install the charged air cooler outlet duct to intake hose. The hose is marked DUCT which connects to the charged air cooler outlet duct. The hose

is marked ENG which connects to the turbocharger. Align the marks on the hose with the alignment marks on the pipe and duct.

21. Position the clamps as shown for proper clearance.

^

Tighten the clamps to 6 Nm (53 inch lbs.).

22. Install the air cleaner outlet duct to the air cleaner.