gmc Workshop Repair Guides

GMC Workshop Service and Repair Manuals

A/C - Noisy/Inoperative|Page 15095 > < A/C - Noisy/Inoperative|Page 15093
Page 1
background image

Expansion Valve: Service and Repair

THERMAL EXPANSION VALVE REPLACEMENT - AUXILIARY

REMOVAL PROCEDURE

1. Remove the evaporator core.
2. Carefully remove the sealer packed around the Thermo Expansion Valve (TXV). Reuse the sealer on the replacement TXV.

IMPORTANT:  Note the mounting location and the orientation of the tube on the core.

3. Remove the clip retaining the capillary tube to the evaporator core.
4. Disconnect the Evaporator tube connections from the TXV.
5. Remove the TXV from the tubes.

INSTALLATION PROCEDURE

1. Install the Thermal Expansion Valve (TXV) to the tubes.

NOTE:  Refer to Fastener Notice in Service Precautions.

2. Connect the Evaporator tube connections from the TXV.

Tighten
Tighten the tube connections to 28 N.m (21 lb ft).

A/C - Noisy/Inoperative|Page 15095 > < A/C - Noisy/Inoperative|Page 15093