K Yukon/Denali 4WD V8-5.7L VIN R (2000)
Alternator: Service and Repair
Generator Replacement
Generator Replacement (CS 144)
REMOVAL PROCEDURE
CAUTION: Refer to Battery Disconnect Caution in Service Precautions.
1. Disconnect the battery negative cable.
2. Disconnect the terminal plug from the back of the generator.
3. Disconnect the battery lead from the back of the generator.
4. Remove the upper fan shroud as needed.
5. Remove the drive belt.
6. Remove the generator mounting bolts holding the generator to the brace and the bracket.
7. Remove the generator.
INSTALLATION PROCEDURE
1. Install the generator.
NOTE: Refer to Fastener Notice in Service Precautions.
2. Perform the following procedure in order to install the generator mounting bolts holding the generator to the bracket and the brace:
2.1. Loosely install the generator mounting bolts holding the generator to the bracket and the brace.
2.2. Install the brace attachment.
2.3. Tighten the generator mounting bolts holding the generator to the bracket and the brace.