S15/T15 2WD Jimmy V6-262 4.3L (1991)
4. Watch the low side gage to be sure vacuum holds for five minutes. If the vacuum holds disconnect the vacuum hose at the gage set and then
proceed to charging.
5. If the vacuum does not hold for five minutes, charge the system with 0.227 kg (8 oz.) Refrigerant-12 and leak check. Discharge the system again
and repair any leaks. Repeat the evacuation procedure.
Discharging System
J 23500-01 Charging Station
Discharging Without J 23500-01
DISCHARGING SYSTEM
Tool Required:
-
J 23500-01 Portable Charging Station
CAUTION: Before replacing any component, discharge the system.
1. Discharge at the low side service fitting.
2. With the ignition turned OFF, remove the protective cap from LOW SIDE service fitting and connect J 23500-01 Gage Set. (Refer to