Thermostatic Air Cleaner: Testing and Inspection

Results of Incorrect Operation 

Hesitation during warm up can be caused by:
-

Heat stove tube disconnected.

-

Missing or damaged air cleaner to TBI gasket.

-

Loose air cleaner cover and air cleaner.

-

Missing air cleaner cover seal.

-

Stuck open damper door.

Lack of power, sluggish, pinging or spongy, on a hot engine check for:
-

Stuck closed damper door.

Air Cleaner Functional Check

-

Remove air cleaner assembly and cool to below 4°C (40°F). The damper should be closed to outside air (cold air).

-

Check condition of air cleaner to throttle body gasket.

-

Reinstall air cleaner and connect heat stove tube at air cleaner snorkel and exhaust manifold.

-

Start engine. Watch damper door in air cleaner snorkel. As air cleaner warms up, damper door should open slowly to outside air (cold air).

-

If air cleaner fails to operate as described, be sure calibrated spring is properly installed and damper door is not binding. 

-

If still inoperative after last step, replace wax pellet actuator assembly and recheck