For minor damage, tape over the wire. If damage is more extensive, replace the faulty segment of the wire. (Refer to the splicing instructions for
copper or shielded cable for the correct procedure.)  See: Wire Repair Procedures/Typical Electrical Repair Procedures/Splicing Copper Wire
Using Splice Clips  See: Wire Repair Procedures/Typical Electrical Repair Procedures/Splicing Copper Wire Using Crimp and Seal Splice
Sleeves  See: Wire Repair Procedures/Typical Electrical Repair Procedures/Splicing Twisted/Shielded Cable

Splicing Copper Wire Using Crimp and Seal Splice Sleeves

Crimp and seal splice sleeves may be used on all types of insulation except tefzel and coaxial to form a one-to-one splice. They are to be used where
there are special requirements such as moisture sealing. Crimp and seal splice sleeves are included in the J 38125 terminal Repair Kit.

Step One: Open the Harness
If the harness is taped, remove the tape. To avoid wire insulation damage, use a sewing "seam ripper" to cut open the harness (available from
sewing supply stores). The crimp and seal splice sleeves may be used on all types of insulation except tefzel and coaxial and may only be used to
form a one-to-one splice.

Step Two: Cut the Wire
Begin by cutting as little wire off the harness as possible. You may need the extra length of wire later if you decide to cut more wire to change the
location of a splice. You may have to adjust splice locations to make certain that each splice is at least 40 mm (1-1/2 in) away from other splices,
harness branches, or connectors. This will help prevent moisture from bridging adjacent splices and causing damage.

Wire Size Conversion Table

Step Three: Strip the Insulation
If it is necessary to add a length of wire to the existing harness, be certain to use the same size as the original wire.

To find the correct wire size, either find the wire on the schematic  and convert the metric size to the equivalent AWG size or use an AWG gage. If
unsure about the wire size, begin with the largest opening in your wire stripper and work down until you get a clean strip of the insulation. Strip
approximately 7.5 mm (5/16 in) of insulation from each wire to be spliced. Be careful to avoid nicking or cutting any of the wires. Check the
stripped wire for nicks or cut strands. If the wire is damaged, repeat this procedure after removing the damaged section.

Crimp And Seal Splice Sleeve Chart

Step Four: Select and Position the Splice Sleeve
Select the proper splice sleeve according to wire size. The splice sleeves and tool nests are color coded.

Diagram Information and Instructions|Page 401 > < Diagram Information and Instructions|Page 399