9.6.

Apply body sealer GM P/N 9984248 around any exposed openings.

9.7.

Install a new fastener GM P/N 11515933.

INSTALLATION PROCEDURE

1. Install the SDM (2) to the vehicle.

NOTE:  Refer to Fastener Notice in Service Precautions.

2. Install the SDM mounting fasteners (1). 

Tighten
Tighten fasteners to 12 N.m (106 lb in).

3. Install the SDM harness connector (3) to the SDM (2).
4. Install the Connector Position Assurance (CPA) (4) to the SDM harness connector (3).
5. Tape the cut carpet to cover the Inflatable Restraint Sensing And Diagnostic Module (SDM).
6. Install the floor console, if equipped.
7. Enable the SIR system.