A/C Blower Fan - Runs Continuously With Ignition Off|Page 9739 > < A/C Blower Fan - Runs Continuously With Ignition Off
Page 1
background image

Blower Motor: All Technical Service Bulletins
A/C Blower Fan - Runs Continuously With Ignition Off

File In Section: 1 - HVAC

Bulletin No.: 86-12-08

Date: June, 1998

Subject:
HVAC Blower Fan Runs Continuously with Ignition Off (Replace A/C Control Assembly)

Models:
1998 Chevrolet and GMC S/T Models 
1998 Oldsmobile Bravada
with RPO C68

Condition

Some owners may comment that the blower fan keeps running after the ignition is turned OFF.

Cause

If the ignition key is turned off within a very short time window, the blower speed output timer may not reset during the power down sequence. When
this occurs, the control assembly will continue to output a 8hz signal to the pulse width modulation (PWM) blower driver.

The PWM blower driver is designed to operate at between 30-50hz, but may operate at a frequency as low as 8hz. If the key is turned off during this very
short time window, and a signal of 8hz is triggered, the fan will run until the battery is dead or until the ignition key is cycled on and off.

Correction

Replace the A/C control assembly using the part number(s) listed. Use the Service Procedure in Section 1B of the Service Manual.

Parts Information

Parts are currently available from GMSPO.

Warranty Information

For vehicles repaired under warranty, use:

Labor Operation

Description

Labor Time

D0362

Control Assembly

Labor Operation

(A/C) - Replace

Time