Connecting The Shift Cable To The Carrier

Connecting The Shift Cable To The Vacuum Actuator

INSTALL OR CONNECT 

1. Shift cable housing (11) to the carrier assembly.
2. Bolts (6). Tighten bolts (6) to 48 Nm (36 lbs. ft.).
3. Shift cable (10) to the shift cable housing.

A. The shift cable must be attached to the housing before it is routed.
B. Guide the cable end (136) through the hole in the shift cable housing.
C. Push the cable end into the shift fork shaft (17). It should snap into place.
D. Thread the coupling nut (132) into the housing by hand to avoid cross threading. Tighten coupling nut to 10.0 Nm (90 lbs. in.).

4. Lower the vehicle.
5. Shift cable to the vehicle.

A. Route as shown. 

6. Shift cable to the vacuum actuator (130).

A. Push the cable into the hole in the bracket. The cable end and ferrule should snap together.