gmc Workshop Repair Guides

GMC Workshop Service and Repair Manuals

Hydraulic Fluid Accumulator|Service and Repair|Page 7183 > < P/B Booster Fluid Flow & PRESS Alarm Delay Module|Page 7179
Page 1
background image

Hydraulic Fluid Accumulator: Service and Repair

Hydraulic Brake Booster Accumulator Replacement

^

Tools Required
-

J 26889 Accumulator Piston Compressor

Removal Procedure

Caution:
^

The accumulator contains compressed gas. Always use the proper tools and follow the recommended procedures or personal injury may result Do
not apply heat to accumulator. Do not attempt to repair an inoperative accumulator. Always replace an inoperative accumulator with a new one.
Dispose of an inoperative accumulator by drilling a 1.5 mm (1/16 inch) diameter hole through the end of the accumulator can, opposite the O-ring.

^

Push rod removal is not recommended. Improper staking of the push rod to the Hydroboost reaction piston can result in a loss of brakes. If the rod
or seals require service, the entire unit must be replaced.

1. Depress brake pedal at least ten times to relieve pressure in the accumulator.

Important:  After the next step, remember to support the master cylinder.

2. Damage to the brake lines can occur if the master cylinder is not supported.
3. Remove the master cylinder from the hydraulic booster.

4. Place the J 26889 over the end of the accumulator.
5. Install the nut on the stud.
6. Depress the accumulator with a C-clamp. If accumulator doesn't move with moderate pressure, remove the C-clamp and depress brake pedal ten

times to relieve pressure in the accumulator.

Hydraulic Fluid Accumulator|Service and Repair|Page 7183 > < P/B Booster Fluid Flow & PRESS Alarm Delay Module|Page 7179