Savana 1/2 Ton Van V8-5.7L VIN R (2001)
1. Install the surge tank to the cowl tabs.
Notice: Refer to Fastener Notice in Service Precautions.
2. Install the surge tank retaining bolt.
^
Tighten the bolt to 6 Nm (53 inch lbs.).
3. Connect the coolant level sensor electrical connector.
4. Install the outlet hose to the bottom of the surge tank.
5. Install the inlet hose to the top of the radiator and to the surge tank.
6. Install the overflow hose to the top of the surge tank.
7. Fill the surge tank with coolant to the proper level.