Typical vacuum drop is 7 - 10 kPa (2 - 3 in Hg). If the vacuum does not remain steady, refer to Excessive Vacuum Drop Diagnosis.
9. Remove the J 43485 and the J 35555.
10. Reinstall the pump reservoir cap.
11. Start the engine. Allow the engine to idle.
12. Turn off the engine.
13. Verify the fluid level. Repeat steps 11-13 until the fluid stabilizes.
Important: Do not turn steering wheel to lock.
14. Start the engine. Allow the engine to idle.
15. Turn the steering wheel 180-360 degrees in both directions 5 times.
16. Switch the ignition off.
17. Verify the fluid level.
18. Remove the pump reservoir cap.
19. Attach the J 43485 to the J 35555 or equivalent.
20. Place the J 43485 on or in the pump reservoir filler neck.
21. Apply a vacuum of 68 kPa (20 in Hg) maximum.
22. Wait 5 minutes.
23. Remove the J 43485 and the J 35555.
24. Verify the fluid level.