Savana 1500 RWD V6-4.3L (2007)
1. Install the lower mode actuator.
2. Press lower mode actuator on until you hear tabs engage.
3. Install the I/P carrier.
Recirculation Actuator Replacement
Recirculation Actuator Replacement
Tools Required
J 39400-A Electronic Halogen Leak Detector
Removal Procedure
1. Recover the refrigerant from the A/C system. Refer to Refrigerant Recovery and Recharging.
2. Disconnect the low pressure sensor electrical connector.
3. Disconnect the blower motor electrical connector.
4. Disconnect the blower motor resistor assembly electrical connector.
5. Remove the evaporator outlet hose retaining nuts (4, 5).
6. Remove the retaining nut (3) from the evaporator inlet tube (5).
7. Remove the evaporator inlet tube from the evaporator.
8. Remove the sealing washers.