Refer to Fastener Notice in Service Precautions.

Install the bolt to the combination valve and the frame.
^

Tighten the bolt to 10 Nm (88 inch lbs.).

3. Connect the front and rear brake pipes to the combination valve.

^

Tighten the brake pipe fittings to the combination valve to 30 Nm (22 ft. lbs.).

4. Connect the electrical connector to the combination valve.
5. Bleed the brake hydraulic system.