gmc Workshop Repair Guides

GMC Workshop Service and Repair Manuals

Positive Crankcase Ventilation > < EGR Valve|Service and Repair
Page 2
background image

2. Install the EGR valve.

NOTE:  Refer to Fastener Notice in Service Precautions.

3. Install the valve to flange fasteners.

Tighten
-

Tighten the fasteners the first time to 10 N.m (89 lb in) each.

-

Tighten the fasteners a final time to 25 N.m (18 lb ft) each.

1. Connect the electrical connector.
2. Install the air cleaner assembly.

Positive Crankcase Ventilation > < EGR Valve|Service and Repair