gmc Workshop Repair Guides

GMC Workshop Service and Repair Manuals

Charging System - SES/Generator Lamp ON/Engine No Start|Page 5615 > < Battery Cable Replacement (Positive)|Page 5605
Page 1
background image

Alternator: Customer Interest
Charging System - SES/Generator Lamp ON/Engine No Start

Bulletin No.: 01-06-03-010A

Date: July 17, 2003

TECHNICAL

Subject:
Drive Belt Noise, Service Engine Soon/Generator Light Illuminated, Engine Will Not Start or Quits Running (Replace Generator and Reseal Windshield
Water Runoff Duct)

Models:
2001-2002 Chevrolet Express Van Models
2001-2002 GMC Savana Van Models

Supercede:

This bulletin is being revised to add model years and add a step to the Correction procedure. Please discard Corporate Bulletin Number 01-06-03-010
(Section 06 - Engine/Propulsion System).

Condition

Some customers may comment on one or more of the following conditions:

^

Drive belt noise (squeal)

^

Service Engine Soon Light illuminated

^

Generator Light illuminated

^

Engine will not start

^

Engine quits running

This condition is most prevalent at outside temperatures below 0°C (32°F).

Cause

The plastic windshield water runoff duct may not be properly sealed or fastened to the cowl located directly above the generator. This can lead to runoff
water from the windshield being directed onto the generator. During times of freezing temperatures, the ingested water can become frozen inside the
generator, resulting in generator damage. 

Correction

Replace the generator and reseal the windshield water runoff duct mating surface to the cowl and fastening it onto the studs in the cowl, ensuring that it is
properly sealed at the three studs. Use the procedure and part numbers listed below.

1.

Remove the generator. Refer to the Generator Replacement procedure in the Engine Electrical sub-section of the Service Manual.

2.

Inspect and replace the drive belt, if necessary.