Manifold Pressure/Vacuum Sensor > < Malfunction Indicator Lamp|Testing and Inspection
Page 2
background image

3. Ignition ON, connect a 3A fused jumper wire between the MIL control circuit terminal X2-30 and ground. The MIL should illuminate.

‹› If the MIL does not illuminate, test the MIL control circuit for a short to voltage, or an open/high resistance. If the circuit tests normal, replace

the IPC/bulb.

4. If all circuits/connectors test normal, replace the ECM.

Repair Instructions

Perform the Diagnostic Repair Verification   (See: Testing and Inspection/Diagnostic Trouble Code Tests and Associated Procedures/Verification Tests
and Procedures) after completing the diagnostic procedure.

*

Instrument Cluster Replacement   (See: Instrument Panel, Gauges and Warning Indicators/Instrument Cluster / Carrier/Service and Repair)

*

Control Module References   (See: Testing and Inspection/Programming and Relearning) for ECM and ICM replacement, setup, and programming