gmc Workshop Repair Guides

GMC Workshop Service and Repair Manuals

Diagram Information and Instructions|Page 10654 > < Diagram Information and Instructions|Page 10652
Page 17
background image

9. Use J 38125-12A to gently lift the terminal retaining tab while gently pulling the wire out of the back of the connector. Always remember never

use force when pulling a terminal out of a connector. If the terminal is severely bent or damaged, it may be possible on some connectors to push
the wire out of the front of the connector instead of pulling it through. This will prevent damage to the internal seals of the connector. Once the
terminal is pushed out of the connector, cut the wire as close to the terminal as possible and pull the wire through the connector.

REPAIR PROCEDURE

The Micro-Pack 100W connectors have small terminals that are difficult to handle and hold when crimping. In order to aid the technician when
crimping these terminals, a new crimping tool was developed. The J 38125-101 (W jaw) crimping tool was developed to crimp Micro-Pack 100W
terminals. The J 38125-101 (W jaw) crimping tool has a terminal holding block that will hold the terminal in place while the terminal is being
crimped. After the terminal is removed from the connector perform the following procedure in order to repair Micro-Pack 100 terminals.
1. Cut the wire as close to the terminal as possible.

IMPORTANT:  After cutting the damaged terminal from the wire, determine if the remaining wire is long enough to reach the connector without
putting a strain on the wire. If the wire is not long enough, splice a small length of the same gage wire to the existing wire, then crimp the new terminal
on the added wire.

2. Strip 5 mm (3/16 in) of insulation from the wire.

3. Depress the spring loaded locator of the J 38125-101 (W jaw) crimping tool until the terminal holder is completely visible.

Diagram Information and Instructions|Page 10654 > < Diagram Information and Instructions|Page 10652