gmc Workshop Repair Guides

GMC Workshop Service and Repair Manuals

Diagram Information and Instructions|Page 43 > < Diagram Information and Instructions|Page 41
Page 26
background image

-

Disconnect the harness at both ends of the suspected circuit where it connects either to a component or to other harnesses.

-

If the system that is being diagnosed has a specified pinout or breakout box, it may be used in order to simplify connecting the DMM to the circuit
or for testing multiple circuits quickly.

Troubleshooting With A Test Lamp

TROUBLESHOOTING WITH A TEST LAMP

TOOLS REQUIRED

J 35616-200 Test Light   Probe Kit

NOTE:  Refer to Test Probe Notice in Service Precautions.

A test lamp can simply and quickly test a low impedance circuit for voltage.

The J 35616-200 is Micro-Pack compatible and comprised of a 12-volt light bulb with an attached pair of leads.

To properly operate this tool use the following procedures.

When testing for voltage:
1. Attach 1 lead to ground.
2. Touch the other lead to various points along the circuit where voltage should be present.
3. When the bulb illuminates, there is voltage at the point being tested.

When testing for ground:
1. Attach 1 lead to battery positive voltage.
2. Touch the other lead to various points along the circuit where ground should be present.
3. When the bulb illuminates, there is ground at the point being tested.

Using Connector Test Adapters

USING CONNECTOR TEST ADAPTERS

NOTE:  Do not insert test equipment probes (DVOM etc.) into any connector or fuse block terminal. The diameter of the test probes will deform most
terminals. A deformed terminal will cause a poor connection, which will result in a system failure. Always use the J-35616 GM-Approved Terminal Test
Kit or the J 42675 Flat-Wire Probe Adapter in order to front probe terminals. Do not use paper clips or other substitutes to probe terminals.

When using the J-35616 GM-Approved Terminal Test Kit, ensure the terminal test adapter choice is the correct size for the connector terminal. Do not
visually choose the terminal test adapter because some connector terminal cavities may appear larger than the actual terminal in the cavity. Using a
larger terminal test adapter will damage the terminal. Refer to the J-35616 GM-Approved Terminal Test Kit label on the inside of the J-35616
GM-Approved Terminal Test Kit for the correct adapter along with the connector end view for terminal size.

Using Fused Jumper Wires

 

USING FUSED JUMPER WIRES

TOOLS REQUIRED

J 36169-A Fused Jumper Wire

IMPORTANT:  A fused jumper may not protect solid state components from being damaged.

The J 36169-A includes small clamp connectors that provide adaptation to most connectors without damage. This fused jumper wire is supplied with a
20-A fuse which may not be suitable for some circuits. Do not use a fuse with a higher rating than the fuse that protects the circuit being tested.

Bosch Connectors (BSK)

BOSCH CONNECTORS (BSK)

TOOLS REQUIRED

J-38125 Terminal Repair Kit

TERMINAL REMOVAL PROCEDURE

1. Disconnect the connector from the component.
2. Remove the wire dress cover, if necessary.

Diagram Information and Instructions|Page 43 > < Diagram Information and Instructions|Page 41