gmc Workshop Repair Guides

GMC Workshop Service and Repair Manuals

Variable Valve Timing Solenoid > < Camshaft Position Actuator Magnet Replacement|Page 4774
Page 2
background image

1. Install the a NEW CMP actuator solenoid valve until snug.

With the CMP actuator properly positioned onto the camshaft, the CMP actuator solenoid valve can be threaded completely into the camshaft
using light hand pressure. Tighten by hand until snug.

Notice: Refer to Fastener Notice.

2. Tighten the CMP actuator solenoid valve.

1. Tighten the solenoid valve a first pass to 65 N.m (48 lb ft).
2. Tighten the solenoid valve a final pass and additional 90 degrees using J 45059.

3. Install the CMP actuator magnet.

Variable Valve Timing Solenoid > < Camshaft Position Actuator Magnet Replacement|Page 4774