Terminal Insertion Procedure

After the terminal is replaced, perform the following procedure in order to insert the terminal.

1. Slide the new terminal into the correct cavity at the back of the connector.
2. Push the terminal into the connector until it locks into place. The new terminal should be even with the other terminals. Insure that the terminal is

locked in place by gently pulling on the wire.

3. To assemble the connector, reverse the connector disassembly procedure.

Tyco/AMP Connectors (CM 42-Way)

Tyco/AMP Connectors (CM 42-Way)

Special Tools

*

EL-38125-580 - Terminal Release Tool Kit

*

J-38125-12A - Terminal Release Tool

For equivalent regional tools, refer to Special Tools   (See: Power and Ground Distribution/Tools and Equipment).

Terminal Removal Procedure

1. Locate the connector position assurance (CPA) on the connector body and pull the CPA out. The CPA is on the wire harness side of connector.
2. Disconnect the connector from the component.

3. Use a small flat-bladed tool to gently pry off the dress cover by inserting the tool under the cover opposite the harness side and prying up. 
4. Remove the cover.