gmc Workshop Repair Guides

GMC Workshop Service and Repair Manuals

Diagram Information and Instructions|Page 12582 > < Diagram Information and Instructions|Page 12580
Page 118
background image

7. View of the male half of the connector with female terminals.
8. While holding the removal tool in place, gently pull the wire out of the back of the connector. Always remember never use force when pulling a

terminal out of a connector.

9. Repair the terminal by following the Repairing Connector Terminals (Terminated Lead Repair)   (See: General Electrical Diagnostic

Procedures/Connector Repairs/Repairing Connector Terminals (Terminated Lead Repair))Repairing Connector Terminals (Terminal Repair)   (
See: General Electrical Diagnostic Procedures/Connector Repairs/Repairing Connector Terminals (Terminal Repair)) procedure.

10. Insert the repaired terminal back into the cavity. Repeat the diagnostic procedure to verify the repair and reconnect the connector bodies.

Repairing Connector Terminals (Terminated Lead Repair)

Repairing Connector Terminals (Terminated Lead Repair)

Special Tools

*

EL-38125-10 - Splice Sleeve Crimp Tool

*

J-38125-5 - Ultra Torch

For equivalent regional tools, refer to Special Tools   (See: Power and Ground Distribution/Tools and Equipment).

Note:  All repairs near the engine manifold, turbo engine and all exhaust pipes should follow the High Temperature Wiring Repairs procedures.

For high temperature wiring repairs, refer to High Temperature Wiring Repairs   (See: Testing and Inspection/Component Tests and General
Diagnostics/General Electrical Diagnostic Procedures/Wiring Repairs/High Temperature Wiring Repairs).

Terminated leads are terminals that are crimped onto wires. The terminated lead can be used throughout the vehicle since it is designed for temperatures
up to 150°C. The length of the wire is 450 mm.

1. Use the connector end view to identify the correct terminated lead.
2. The terminated lead package should include a DuraSeal splice sleeve. If not, use the chart to in Splicing Copper Wire Using Splice Sleeves to

identify the correct DuraSeal splice sleeve, refer to Splicing Copper Wire Using Splice Sleeves   (See: Testing and Inspection/Component Tests
and General Diagnostics/General Electrical Diagnostic Procedures/Wiring Repairs/Splicing Copper Wire Using Splice Sleeves).

Repairing Connector Terminals (Terminal Repair)

Repairing Connector Terminals (Terminal Repair)

Special Tools

*

J-38125 - Terminal Repair Kit

*

J-38125-6 - Crimp Tool

*

J-38125-7 - Crimp Tool

*

J-38125-8 - Crimp Tool

Diagram Information and Instructions|Page 12582 > < Diagram Information and Instructions|Page 12580