J-38125-64 - Crimp Tool

*

J-38125-101 - Crimp Tool

*

J-38125-641 - Crimp Tool

*

J-38125-642 - Crimp Tool

*

J-38125-643 - Crimp Tool

For equivalent regional tools, refer to Special Tools   (See: Power and Ground Distribution/Tools and Equipment).

Use the following repair procedures to repair each type of terminal:

*

For push to seat terminals, refer to Delphi Connectors (Steering Gear)   (See: Testing and Inspection/Component Tests and General
Diagnostics/General Electrical Diagnostic Procedures/Connector Repairs/Delphi Connectors (Steering Gear))Delphi Connectors (12-Way)   (See:
Testing and Inspection/Component Tests and General Diagnostics/General Electrical Diagnostic Procedures/Connector Repairs/Delphi Connectors
(12-Way))Delphi Connectors (Micro.64)   (See: Testing and Inspection/Component Tests and General Diagnostics/General Electrical Diagnostic
Procedures/Connector Repairs/Delphi Connectors (Micro .64))Delphi Connectors (Micro-Pack 100W)   (See: Testing and Inspection/Component
Tests and General Diagnostics/General Electrical Diagnostic Procedures/Connector Repairs/Delphi Connectors (Micro-Pack 100W))Delphi
Connectors (Pull To Seat)   (See: Testing and Inspection/Component Tests and General Diagnostics/General Electrical Diagnostic
Procedures/Connector Repairs/Delphi Connectors (Pull to Seat))Delphi Connectors (Push To Seat)   (See: Testing and Inspection/Component
Tests and General Diagnostics/General Electrical Diagnostic Procedures/Connector Repairs/Delphi Connectors (Push to Seat))Delphi Connectors
(Weather Pack)   (See: Testing and Inspection/Component Tests and General Diagnostics/General Electrical Diagnostic Procedures/Connector
Repairs/Delphi Connectors (Weather Pack)).

*

For pull to seat terminals, refer to Delphi Connectors (Steering Gear)   (See: Testing and Inspection/Component Tests and General
Diagnostics/General Electrical Diagnostic Procedures/Connector Repairs/Delphi Connectors (Steering Gear))Delphi Connectors (12-Way)   (See:
Testing and Inspection/Component Tests and General Diagnostics/General Electrical Diagnostic Procedures/Connector Repairs/Delphi Connectors
(12-Way))Delphi Connectors (Micro.64)   (See: Testing and Inspection/Component Tests and General Diagnostics/General Electrical Diagnostic
Procedures/Connector Repairs/Delphi Connectors (Micro .64))Delphi Connectors (Micro-Pack 100W)   (See: Testing and Inspection/Component
Tests and General Diagnostics/General Electrical Diagnostic Procedures/Connector Repairs/Delphi Connectors (Micro-Pack 100W))Delphi
Connectors (Pull To Seat)   (See: Testing and Inspection/Component Tests and General Diagnostics/General Electrical Diagnostic
Procedures/Connector Repairs/Delphi Connectors (Pull to Seat))Delphi Connectors (Push To Seat)   (See: Testing and Inspection/Component
Tests and General Diagnostics/General Electrical Diagnostic Procedures/Connector Repairs/Delphi Connectors (Push to Seat))Delphi Connectors
(Weather Pack)   (See: Testing and Inspection/Component Tests and General Diagnostics/General Electrical Diagnostic Procedures/Connector
Repairs/Delphi Connectors (Weather Pack)).

Note:  The first step for all terminal repairs is to find the connector end view in SI.

Cable Seal Terminals

1. Cut off the terminal between the core and the insulation crimp to minimize any wire loss.
2. Remove the old seal.
3. Apply the correct cable seal, per the wire gauge size, from the kit. Slide the seal back along the wire to enable removal of the insulation.
4. To minimize wire loss, remove only the insulation required.
5. Using the connector end view, determine the correct crimp tool and crimp jaw.
6. Align the seal with the end of the cable insulation.
7. Position the stripped wire and seal in the terminal. 
8. Hand Crimp the core wings first.
9. Hand Crimp the insulation wings around the seal and the cable.

10. Solder all of the hand crimp terminals except the Micro-Pack 100 and 0.64 sizes. 

Unsealed Terminals

1. Cut off the terminal between the core and the insulation crimp to minimize any wire loss.
2. To minimize wire loss, remove only the insulation required.
3. Position the stripped wire in the terminal. 
4. Hand Crimp the core wings first.
5. Hand Crimp the insulation wings around the cable.
6. Solder all of the hand crimp terminals except the Micro-Pack 100 and 0.64 sizes.

Micro-Pack 100W Size Terminal

The Micro-Pack 100W connectors have small terminals that are difficult to handle and hold when crimping. In order to aid the technician when crimping
these terminals, a new crimping tool was developed. The J 38125-101 (W jaw) crimping tool was developed to crimp Micro-Pack 100W terminals. The J
38125-101 (W jaw) crimping tool has a terminal holding block that will hold the terminal in place while the terminal is being crimped. After the terminal
is removed from the connector perform the following procedure in order to repair Micro-Pack 100 terminals.

1. Cut the wire as close to the terminal as possible.

Note:  After cutting the damaged terminal from the wire, determine if the remaining wire is long enough to reach the connector without putting a
strain on the wire. If the wire is not long enough, splice a small length of the same gauge wire to the existing wire, then crimp the new terminal on