Diagram Information and Instructions|Page 8018 > < Diagram Information and Instructions|Page 8016
Page 8
background image

Danger: This procedure should not be performed on high voltage circuits. Performing this procedure on high voltage circuits may result in
serious injury or death.

Note:  Always be sure to reinstall the connector position assurance (CPA) and terminal position assurance (TPA) when reconnecting connectors or
replacing terminals.

Front probe

Disconnect the connector and probe the terminals from the mating side (front) of the connector.

Caution:  Do not insert test equipment probes (DMM etc.) into any connector or fuse block terminal. The diameter of the test probes will deform most
terminals. A deformed terminal will cause a poor connection, which will result in a system failure. Always use the EL-38125-580 GM Approved
Terminal Release Tool Kit in order to front probe terminals. Do not use paper clips or other substitutes to probe terminals. 

When using the EL-38125-580 GM Approved Terminal Release Tool Kit , ensure the terminal test adapter choice is the correct size for the connector
terminal. Do not visually choose the terminal test adapter because some connector terminal cavities may appear larger than the actual terminal in the
cavity. Using a larger terminal test adapter will damage the terminal. Refer to the EL-38125-580 GM Approved Terminal Release Tool Kit label on the
inside of the EL-38125-580 GM Approved Terminal Release Tool Kit for the correct adapter along with the connector end view for terminal size. 

Note:  When probing female 0.64 terminals, it is important to use the correct adapter. There have been some revisions to the test adapter for 0.64
terminals. The proper adapter for 0.64 terminals is the J-35616-64B which has a gold terminal and a black wire between the base and tip. Failure to use
the proper test adapter may result in damage to the terminal being tested and improper diagnosis.

Refer to the following table as a guide in selecting the correct test adapter for front probing connectors: