gmc Workshop Repair Guides

GMC Workshop Service and Repair Manuals

Discharge Hose Replacement (LGH, LML)|Page 10238 > < Discharge Hose Replacement (LGH, LML)|Page 10236
Page 5
background image

6. Install the discharge hose (1) to the A/C compressor using new sealing washers. Refer to Air Conditioning System Seal Replacement   (See:

Coupler HVAC/A/C Coupler O-ring/Service and Repair/Air Conditioning System Seal Replacement).

7. Install the discharge hose mounting bolt and tighten to 16 Nm (12 lb ft).
8. Evacuate and recharge the A/C system. Refer to Refrigerant Recovery and Recharging (HP2)   (See: Service and Repair)Refrigerant Recovery and

Recharging (Non-HP2)   (See: Refrigerant/Service and Repair).

9. Leak test the fittings of the component using the J 39400-A  .

Suction Hose Replacement (LGH, LML)

Suction Hose Replacement (LGH, LML)

Special Tools

GE-39400-A - Halogen Leak Detector

For equivalent regional tools, Refer toSpecial Tools   (See: Tools and Equipment/Heating, Ventilation, and Air Conditioning)

Removal Procedure

1. Recover the refrigerant. Refer to Refrigerant Recovery and Recharging (HP2)   (See: Service and Repair)Refrigerant Recovery and Recharging

(Non-HP2)   (See: Refrigerant/Service and Repair).

2. Remove the air cleaner assembly. Refer to Air Cleaner Assembly Replacement   (See: Engine, Cooling and Exhaust/Engine/Tune-up and Engine

Performance Checks/Air Cleaner Housing/Service and Repair).

3. Remove the suction hose mounting bolt (1) from the A/C compressor. 
4. Remove the suction hose (2) from the compressor.