gmc Workshop Repair Guides

GMC Workshop Service and Repair Manuals

Procedures|Page 10401 > < Procedures|Page 10399
Page 7
background image

7. Cut the yellow harness connector out of the vehicle, leaving at least 16 cm (6 in) of wire at the connector.
8. Strip 13 mm (0.5 in) of insulation from each of the connector wire leads.

9. Cut two 6.1 m (20 ft) deployment wires from a 0.8 mm (18 gauge) or thicker multi-strand wire. Use these wires to fabricate the driver deployment

harness.

10. Strip 13 mm (0.5 in) of insulation from both ends of the wires.
11. Twist together one end from each of the wires in order to short the wires. Deployment wires shall remain shorted, and not connected to a power

source until you are ready to deploy the inflator module.

12. Twist together the 2 connector wire leads from the high circuits from both stages of the steering wheel module, to one set of deployment wires.

Refer to Component Connector End Views   (See: Diagrams/Connector Views/Connector End Views By Name) in order to determine the correct
circuits.

13. Inspect that the 3-wire connection is secure.

14. Bend flat the twisted connection.

Procedures|Page 10401 > < Procedures|Page 10399