Sierra Classic 1500 2WD V8-5.3L Hybrid (2007)
1. Install the fuse power cable (2) to the fuse holder and high current sensor.
2. Install NEW tie straps (4) securing the fuse power cable to the generator battery carrier.
Notice: Refer to Fastener Notice.
3. Install the fuse power cable nut (3) at the high current sensor.
Tighten the nut to 10 N.m (89 lb in).
4. Install the maxi-fuse.
Battery Positive Cable Replacement - Battery 3 (5.3L Engine w/RPO HP2)
Battery Positive Cable Replacement - Battery 3 (5.3L Engine w/RPO HP2)
Caution: To help avoid personal injury, disable the 36V system anytime you perform service work on or around the generator battery carrier.
The 36V system will still be active after you have disabled the generator battery carrier.
Caution: To help avoid personal injury, always disconnect the 36V generator battery carrier before doing any work to the generator battery
carrier system. To disconnect the generator battery carrier, turn the engine off and turn OFF the service disconnect switch, which is located on
the passenger side of the generator battery carrier.
Removal Procedure
1. Remove the generator battery carrier intermediate cover.
2. Remove the power cable nuts (1) from battery 3 and the high current connector (HCC).