Sierra Classic 2500 2WD V8-6.6L DSL Turbo (2007)
Alternator: Service and Repair
Generator Replacement (6.6L Engine)
Generator Replacement (6.6L Engine)
Removal Procedure
Caution: Refer to Battery Disconnect Caution.
1. Disconnect the negative battery cable.
2. Disconnect the generator electrical connector (1).
3. Remove the drive belt.
4. Remove the positive battery cable from the generator. Perform the following:
1. Slide the boot (3) down to access the terminal stud.
2. Remove the positive cable nut (2).
3. Remove the positive cable.