gmc Workshop Repair Guides

GMC Workshop Service and Repair Manuals

Housing Assembly HVAC > < Discharge Hose Replacement (LB7)|Page 18398
Page 2
background image

Notice:  Refer to Fastener Notice.

3.  Install the suction hose nut to the accumulator.

Tighten the nut to 16 N.m (12 lb ft).

4.  Install the suction hose (2) to the compressor using new sealing washers.
5.  Install the suction hose mounting bolt to the A/C compressor.

Tighten the bolt to 16 N.m (12 lb ft).

6.  Evacuate and recharge the A/C system. Refer to Refrigerant Recovery and Recharging.  See: Service and Repair/Removal and

Replacement/Refrigerant Recovery and Recharging

7.  Leak test the fittings of the component using the J 39400-A.

Housing Assembly HVAC > < Discharge Hose Replacement (LB7)|Page 18398