9. Using the heat torch, apply heat to the crimped area of the barrel.

10. Gradually move the heat barrel to the open end of the tubing:

-

The tubing will shrink completely as the heat is moved along the insulation.

-

A small amount of sealant will come out of the end of the tubing when sufficient shrinkage is achieved.

CONNECTOR POSITION ASSURANCE (CPA)

The connector position assurance (CPA) is a small plastic insert that fits through the locking tabs of a connector. CPAs are used in all SIR System
connectors and also in some connectors of other systems. The CPA ensures that the connector halves cannot vibrate apart. You must have the CPA in
place in order to ensure good contact between the mating terminals of a connection.

TERMINAL POSITION ASSURANCE (TPA)

The terminal position assurance (TPA) insert resembles the plastic combs used in the control module connectors. The TPA keeps the terminal securely
seated in the connector body. Do not remove the TPA from the connector body unless you remove a terminal for replacement.

Splicing Copper Wire Using Splice Clips

SPLICING COPPER WIRE USING SPLICE CLIPS

IMPORTANT:  When making a splice in an area that may be exposed to moisture use a crimp and seal splice sleeve instead of a Splice Clip. Refer to
Splicing Copper Wire Using Splice Sleeves.

TOOLS REQUIRED

J-38125 Terminal Repair Kit
1. Open the harness.

-

If the harness is taped, remove the tape.

-

To avoid wiring insulation damage, use a sewing ripper in order to cut open the harness.

-

If the harness has a black plastic conduit, pull out the desired wire.

2. Cut the wire.

-

Cut as little wire off the harness as possible.

-

Ensure that each splice is at least 40 mm (1.5 in) away from other splices, harness branches and connectors. This helps prevent moisture from
bridging adjacent splices and causing damage.

3. Select the proper size and type of wire.

-

The wire must be of equal or greater size than the original (except fusible link).

-

The wire insulation must have the same or higher temperature rating.
-

Use general purpose insulation for areas that are not subject to high temperatures.

-

Use a cross-linked polyethylene insulated wire for areas where high temperatures are expected.

IMPORTANT:  Use cross-linked polyethylene wire to replace PVC, but do not replace cross-linked polyethylene with PVC.

4. Strip the insulation.

-

Select the correct size opening in the wire stripper or work down from the largest size.

-

Strip approximately 7.5 mm (5/16 in) of insulation from each wire to be spliced.

5. Select the proper clip to secure the splice. Follow the instructions in the J-38125 in order to determine the proper clip size crimp tool and anvil.
6. Overlap the 2 stripped wire ends and hold them between thumb and forefinger.