background image

Auxiliary Power Outlet: Service and Repair
120-Volt Accessory Power Receptacle Replacement

 
120-VOLT ACCESSORY POWER RECEPTACLE REPLACEMENT

CAUTION:

-

To help avoid personal injury, disable the 36V system anytime you perform service work on or around the generator battery carrier. The
36V system will still be active after you have disabled the generator battery carrier.

-

To help avoid personal injury, always disconnect the 36V generator battery carrier before doing any work to the generator battery
carrier system. To disconnect the generator battery carrier, turn the engine off and turn OFF the service disconnect switch, which is
located on the passenger side of the generator battery carrier.

REMOVAL PROCEDURE

1. Disconnect the energy storage box (ESB). 
2. Remove the receptacle outlet screws (2).
3. Remove the receptacle outlet (3) from the receptacle box (1).
4. Disconnect the receptacle electrical connections.

INSTALLATION PROCEDURE

1. Connect the receptacle electrical connections.
2. Install the receptacle outlet (3) to the receptacle box (1).

3. NOTE:  Refer to Fastener Notice.

Install the receptacle outlet screws (2).

12-Volt Accessory Power Receptacle Replacement|Page 16000 > < 12-Volt Accessory Power Receptacle Replacement|Page 15998