gmc Workshop Repair Guides

GMC Workshop Service and Repair Manuals

Solar Sensor, HVAC > < Air Conditioning (A/C) Refrigerant Pressure Sensor Replacement|Page 13804
Page 1
background image

Refrigerant Pressure Sensor / Switch: Service and Repair
Air Conditioning Cycling Switch Replacement

Air Conditioning Cycling Switch Replacement (Non-HP2)

Removal Procedure

1. Disconnect the electrical connector from the A/C low pressure switch.

2. Remove the A/C low pressure switch from the accumulator.
3. Remove the O-ring and discard.

Installation Procedure

1. Install the new O-ring seal to the switch. Refer to Air Conditioning O-Ring Seal Replacement   (See: Coupler HVAC/A/C Coupler O-ring) .

Caution:  Refer to Fastener Caution   (See: Service Precautions/Vehicle Damage Warnings/Fastener Caution) .

2. Install the A/C low pressure switch to the accumulator and tighten to 6 Nm (53 lb in) .
3. Connect the electrical connector to the A/C low pressure switch.
4. Leak test the fittings of the components using the J 39400-A   .

Solar Sensor, HVAC > < Air Conditioning (A/C) Refrigerant Pressure Sensor Replacement|Page 13804