gmc Workshop Repair Guides

GMC Workshop Service and Repair Manuals

Blower Motor > < Air Door Actuator / Motor, HVAC|Service and Repair
Page 1
background image

Air Door Cable: Adjustments

C, K, R & V SERIES

LESS A/C

1.

Disconnect battery ground cable.

2.

Remove glove box and door as an assembly.

3.

Disconnect the respective cable clip and disconnect the cable from door.

4.

Remove the cable retaining screw, then, while holding the cable with pliers, rotate the mounting tab on the cable to lengthen or shorten cable.
Avoid pinching cable too tightly as damage to the cable will result.

5.

Reverse procedure to install.

 WITH A/C

1.

Remove glove box, then loosen cable attaching screw at the selector duct assembly.

2.

Make sure the cable is installed in the bracket on the selector duct assembly, then place temperature lever in ``Cold'' position and hold while
tightening cable attaching screw. 

Blower Motor > < Air Door Actuator / Motor, HVAC|Service and Repair