gmc Workshop Repair Guides

GMC Workshop Service and Repair Manuals

Wiring Harness > < Electrical - Intermittent MIL/DTC P2138/Reduced Power|Page 4888
Page 1
background image

Multiple Junction Connector: All Technical Service Bulletins
Electrical Connector - Terminal Checking Procedure

GMC NUMBER:

91-8A-28

GROUP:

8A-ELECTRICAL TROUBLESHOOTING

DATE:

OCTOBER, 1990

CORPORATE
NUMBER:

018115

SUBJECT:

PROCEDURE FOR CHECKING CONNECTOR TERMINAL CONTACT

MODELS:

ALL TRUCKS, ALL MODELS YEARS

When diagnosing an electrical system that utilizes Metri-Pack 150/280/480/630 series terminals (refer to Terminal Repair Kit J 38125-4 instruction
manual for terminal identification), it is important to check terminal contact between a connector and component, or between in-line connectors, before
replacing a suspect component.

Frequently, a diagnostic chart leads to a step that reads: "Check for poor connection or replace...". Mating terminals must be inspected to assure good
terminal contact. A poor connection between the male and female terminal at a connector may be the result of contamination or deformation.

Contamination is caused by the connector halves being improperly connected, a missing or damaged connector seal, or damage to the connector itself,
exposing the terminals to moisture and dirt. Contamination, usually to underhood or underbody connectors, leads to terminal corrosion, causing an open
circuit or intermittently open circuit.

Deformation is caused by probing the mating side of a connector terminal without the proper adapter, improperly joining the connector halves or
repeatedly separating and joining the connector halves. Deformation, usually to the female terminal contact tang, can result in poor terminal contact,
causing an open or intermittently open circuit.
Follow the procedure below to check terminal contact.
1.

Separate the connector halves, refer to Terminal Repair Kit J 38125-4 instruction manual.

2.

Inspect the connector halves for contamination. Contamination will result in a white or green build-up within the connector body or between
terminals causing high terminal resistance, intermittent connection or an open circuit. An underhood or underbody connector that shows signs of
contamination should be replaced in its entirety, terminals, seals and connector body.

3.

Using an equivalent male terminal from the Terminal Repair Kit J 38125-2, check the retention force of the female terminal in question by
inserting and removing the male terminal to the female terminal in the connector body. Good terminal contact will require a certain amount of
force to separate the terminals.

4.

Using an equivalent female terminal from the Terminal Repair Kit J 38125-2, compare the retention force of this terminal to the female terminal in
question by joining and separating the male terminal to the good female terminal, and then joining and separating the male terminal to the female
terminal in question. If the retention force is significantly different between the two female terminals, replace the female terminal in question, refer
to Terminal Repair Kit J 38125-2.