Syclone V6-262 4.3L Turbo (1991)
INSTALL OR CONNECT
1. Blower case (140) with the accumulator (4).
IMPORTANT: Add 0.057 kg (2 oz.) of clean refrigerant oil PLUS an amount equal to that drained.
2. Refrigerant inlet line (108) to the accumulator (4).
IMPORTANT: Add 0.057 kg (2 oz.) of clean refrigerant oil PLUS an amount equal to that drained.
-
Use clean 525 viscosity refrigerant oil on the seal.
-
Tighten connector to 24 Nm (18 ft. lbs.).
3. Electrical connection (154).
4. Negative battery cable.
5. Charge air cooler.
6. Refrigerant to the system.
-
Evacuate, charge and leak test.