V 2500 P/U 4WD V6-262 4.3L (1987)
FIGURE 1
Connector Bleed Assembly Installation Procedure
1.
Disconnect the EGR vacuum line currently on port "J" on the front of the TBI unit. See Figure No.1.
2.
Install connector bleed assembly, P/N 10105820 on port "J" of the TBI unit.
3.
Reconnect the EGR vacuum line removed from port "J" to the open end of the connector bleed assembly.
Labor Operation
Labor
Number
Time
Description
T7455
.3 Hr
Identify existing PROM and install connector bleed
assembly.
Add
.2 Hr
To change PROM if necessary.