Yukon/Denali XL 1500 2WD V8-6.0L VIN U (2005)
3. Remove the recirculation actuator retaining screws.
4. Remove the recirculation actuator.
INSTALLATION PROCEDURE
1. Install the recirculation actuator.
2. Install the recirculation actuator retaining screws.
NOTE: Refer to Fastener Notice in Service Precautions.
Tighten the screws to 1.6 N.m (14 lb in).
3. Connect the electrical connector to the recirculation actuator (1).
4. Install the air distribution duct.
Recirculation Actuator (Visteon)
RECIRCULATION ACTUATOR REPLACEMENT (VISTEON)
REMOVAL PROCEDURE
1. Remove the HVAC module assembly.
2. Remove the screws from the evaporator core cover (1).
3. Remove the evaporator core cover (1) from the HVAC module assembly (2).