Yukon 4WD V8-5.3L (2008)
2. Disconnect the electrical connection from the recirculation actuator (1).
3. Remove the recirculation actuator retaining screws.
4. Remove the recirculation actuator.
Installation Procedure
1. Install the recirculation actuator.
Notice: Refer to Fastener Notice.
2. Install the recirculation actuator retaining screws.
Tighten the screws to 1.6 N.m (14 lb in).
3. Connect the electrical connector to the recirculation actuator (1).
4. Install the air distribution duct.
5. Re-calibrate the recirculation actuator. Refer to Actuator Recalibration. See: Testing and Inspection/Programming and Relearning
Temperature Valve Actuator Replacement - Auxiliary (Behr)
Temperature Valve Actuator Replacement - Auxiliary (Behr)